• 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330
  • 250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330

250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330

EMAX 250kW RLC Load Bank with Anti-Islanding Function is professional testing equipment for inverter testing. It simulates real grid load via RLC combination, focusing on verifying the grid-tied inverter’s anti-islanding...


Brand: Emax
SKU:

EMAX 250kW RLC Load Bank with Anti-Islanding Function is professional testing equipment for inverter testing. It simulates real grid load via RLC combination, focusing on verifying the grid-tied inverter’s anti-islanding protection and overall performance.

Customizable in power and voltage, it adopts top-brand electrical accessories (Siemens, ABB, Schneider) for stable long-term operation and low maintenance.

With self-developed patented software, it provides accurate test data. Trusted by renowned customers like Intertek, ECO FLOW, and KSTAR.

Specifications:

  • Max Power: 250kW
  • Rated Voltage: 380V/400V/415V/480 AC
  • Working Cycle: Continuous operation.
  • Load Accuracy: ±3%
  • Remote Control: Modbus-RTU RS485, Modbus TCP/IP, using free software for remote control using a customer-provided laptop, PC, or tablet.
  • Control method: 1. Three phases can be independently adjustable;
    2. Independently adjustable resistive capacitance;
    3. Power adjustment can be automatically performed through software
  • Load step: Resistive load step: minimum 10W, maximum 20kW
    Inductive load step: minimum 10VAR, maximum 20kVAR
    Capacitive load step: minimum 10VAR, maximum 20kVAR
  • Cooling System: Integral forced-air cooling system, bottom/side inlet, up outlet.
  • Noise: 82dB3M
  • Load Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.
  • Safety Features: Over-temperature, over/under voltage, cooling-air loss, and current imbalance protection.
  • Load Connections: Copper Busbar, Camlock connectors are optional.
  • Daisy Chained: Multiple load banks can be hooked together for higher load capacity.
  • Enclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.
  • Weight: 1400kg
  • Size: 1900mm×1800mm×2000mm

 