Liquid cooled load banks are also named water cooled load banks. It's different from the using of fans to cool down the equipment. Liquid cooling load banks mainly use liquid as a refrigerant to take away the temperature. It features 30%-50% power saving and 20-35db noise reduction.

-25%
200kW Liquid Cooling Load Bank Rack IMAX83200 With Manifold 200kW Liquid Cooling Load Bank Rack IMAX83200 With Manifold

200kW Liquid Cooling Load Bank Rack IMAX83200 With Manifold

The 200kW IMAX83200 Liquid Cooling Load Bank Rack is designed to simulate the NVIDIA GB200, as required by our customers....

$15,000.00

$20,000.00

Emax 30kW Liquid Load Bank Front 2 Emax 30kW Liquid Load Bank Front And Rear

30kW Liquid Cooled Load Bank Rack Mounted IMAX8330 With Remote Control

This 30kW rack-mounted liquid-cooled load bank is our latest R&D product, specially designed for data center applications. It features a...

$250.00

4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted IMAX8108 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted IMAX8108

4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted IMAX8108

Water-cooled load bank is a type of load bank used to simulate loads for testing power generation and distribution equipment,...

$250.00

-11%
500KW Water Cooled Load Bank for Data Center Testing IMAX8150 500KW Water Cooled Load Bank for Data Center Testing IMAX8150

500KW Water Cooled Load Bank for Data Center Testing IMAX8150

The 500KW Water Cooled Load Bank features with max 500KW power, and the rated voltage can be customized. It uses...

$8,500.00

$9,500.00

Frequently Asked Questions

  • What Is a Liquid Load Bank?

    Liquid load banks differ from air load banks; they primarily use liquids (pure water or PG25) as the medium to exchange heat, and are widely used in data centers, renewable energy, or industrial energy fields to simulate electrical and thermal loads. For testing CDUs, Chillers, manifolds, Cooling Towers, etc.

  • How to Select the Right Liquid Load Bank?

    Choosing the right liquid load bank is crucial, as it helps us perform simulations and tests efficiently and correctly. The following points should be considered:

    1. Power, voltage, load step, and other information.
    2. Appropriate electrical and hydraulic interfaces.
    3. Parallel operation scenarios, such as Manifold, UQD, and Group Control Software.

  • Emax Liquid Load Bank Features?

    Emax's liquid load bank is one of the most advanced in the world, featuring ultra-high energy density, full new heating material, and fully intelligent capture of liquid data such as temperature, flow rate, and pressure. It can also accurately provide feedback on parameters such as power, current, and voltage.

Clicky