• 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S
  • 20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S

20kW Liquid-Cooled Load Banks for In-Rack CDU Testing-EA8121S

The EA8121S 20kW liquid-cooled load bank is tailor-made for performance verification of in-rack CDU coolant distribution units in liquid-cooled data centers. It adopts a cold plate liquid cooling layout to...


Brand: Emax
SKU: EA8121S

The EA8121S 20kW liquid-cooled load bank is tailor-made for performance verification of in-rack CDU coolant distribution units in liquid-cooled data centers. It adopts a cold plate liquid cooling layout to reach 95% thermal efficiency for authentic high-density heat source simulation. Fitted with UQD liquid cooling connectors, it supports hot swapping and delivers outstanding fluid leakage prevention for quick field deployment. This compact 1U rackmount module has a single-unit power rating of 7kW, with up to 200 units paralleled for flexible power expansion. It enables real-time acquisition and monitoring of coolant flow, pressure, and temperature data for precise test condition tracking. Equipped with multi-layer protective logic against overcurrent, overvoltage, low flow, overtemperature, and overpressure, the device ensures stable long-duration operation. Remote communication and networked control further simplify centralized test management for data center commissioning and validation tasks.

  • Voltage: 230V/240V/380V/400V/415V/480V
  • Working Cycle: Continuous operation.
  • Ambient temperature: -10℃~45℃/14℉~113℉
  • Operating environment humidity: 0~95%
  • Dimensions: Height 3U, W483 * H133 * D800mm
  • Instrumentation: Digital metering (V, A, kW) and data logging.
  • Control Power: Via external 220-240V AC / Internal Testing circuit.
  • Inlet temperature: -10℃-50℃/14℉ ~ 122℉
  • Outlet temperature: ≤60℃/ 140℉
  • Inlet/outlet connector: UQD08/Tri-clamps.
  • Load Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge. 
  • Safety Features: Over-temperature, over/under voltage, inlet/outlet over temperature, inlet/outlet over pressure, low flow rate, and current imbalance protection.
  • Load Connections: C14/C20/IEC industry plug.
  • Daisy Chained: Multiple load banks can be hooked together for higher load capacity.
  • Chassis: Rack-mount design, perfectly compatible with standard 19-inch racks.