• 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S
  • 4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S

4KW/6KW/8KW/10KW Water Cooled Load Bank Rack Mounted EA8112S

This is a water-cooled load bank, a type of load bank used to simulate loads for testing power generation and distribution equipment, such as generators or uninterruptible power supplies (UPS)....


Brand: Emax
SKU: EA8112S

This is a water-cooled load bank, a type of load bank used to simulate loads for testing power generation and distribution equipment, such as generators or uninterruptible power supplies (UPS). Unlike traditional air-cooled load banks, which dissipate heat through fans, cold plate water-cooled load banks use water as the cooling medium to manage the heat generated during the testing process.

  • Working Cycle: Continuous operation.
  • Ambient temperature: -10℃~50℃
  • Operating environment humidity: 0~95%
  • Dimensions: Height 3U, 433* 130 (panel height is 132) * 500
  • Instrumentation: Digital metering (V, A, kW) and data logging.
  • Control Power: Via external 400V AC or customized.
  • Inlet water temperature: 5-40℃
  • Load Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.
  • Safety Features: Over-temperature, over/under voltage, pressure, flow rate, and current imbalance protection.
  • Load Connections: Copper Busbar, Camlock connectors are optional.
  • Daisy Chained: Multiple load banks can be hooked together for higher load capacity. Modbus RTU RS-485 protocol. 
  • Enclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.