• 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100
  • 100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100

100KW RCD Non linear 400V AC Load Bank Ups Testing IMAX53100

RCD load is a nonlinear simulation load that can be used to test UPS power supplies, inverter power supplies, etc. to understand their true working ability when carrying nonlinear loads...


Brand: Emax
SKU: IMAX53100

RCD load is a nonlinear simulation load that can be used to test UPS power supplies, inverter power supplies, etc. to understand their true working ability when carrying nonlinear loads such as computers and network equipment. By accurately detecting the power output power and quality of the power supply, it can be avoided that it cannot drive the load or pollute the power grid during actual use, thereby ensuring power supply safety.

This equipment can meet three test methods: 1. A three-phase AC source (can meet the three-phase four-wire/two-phase three-wire test requirements) 2. A single-phase AC source 3. Three independent single-phase AC sources

Specifications:

  • Max Power: 100kVA
  • Rated Voltage: 230V/380V/400V/415V AC
  • Working Cycle: Continuous operation.
  • Load Accuracy: ±3%
  • Remote Control: RS485, Modbus-RTU, using free software for remote control using a customer provided laptop, PC, or tablet.
  • Power Factor: 0.7~1 (adjustable)
  • Crest Factor: 2~3
  • Load step: 100W
  • Cooling System: Integral forced-air cooling system, bottom/side inlet, up outlet.
  • Noise: 70dB3M
  • Load Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.
  • Safety Features: Over-temperature, over/under voltage, cooling-air loss, and current imbalance protection.
  • Load Connections: Copper Busbar, Camlock connectors are optional.
  • Daisy Chained: Multiple load banks can be hooked together for higher load capacity.
  • Enclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.
  • Weight: 460kg
  • Size: 950*1150*1750MM 

 