• RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312
  • RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312

RLC Load Bank Anti Island Testing 120kW 400VAC IMAX3312

The RLC anti-islanding test load is one of the most important core devices in a grid-connected inverter test platform. When the grid loses power, the photovoltaic system continues to supply...


Brand: Emax
SKU:

The RLC anti-islanding test load is one of the most important core devices in a grid-connected inverter test platform. When the grid loses power, the photovoltaic system continues to supply power to a portion of the de-energised grid.

The Emax RLC anti-islanding load bank adopts the latest R&D design, fully complies with VDE and IEC standards, and features self-developed anti-islanding software with independent intellectual property rights. It can also be customised with different voltages and load steps according to customer requirements to meet various operating conditions.

Specifications:

  • Max Power: 120kW
  • Rated Voltage: 380V/400V/415V/480 AC
  • Working Cycle: Continuous operation.
  • Load Accuracy: ±3%
  • Remote Control: RS485, Modbus-RTU, using free software for remote control using a customer-provided laptop, PC, or tablet.
  • Control method: 1. Three phases can be independently adjustable;
    2. Independently adjustable resistive capacitance;
    3. Power adjustment can be automatically performed through software
  • Load step: Resistive load step: minimum 10W, maximum 20kW
    Inductive load step: minimum 10VAR, maximum 20kVAR
    Capacitive load step: minimum 10VAR, maximum 20kVAR
  • Cooling System: Integral forced-air cooling system, bottom/side inlet, up outlet.
  • Noise: 80dB3M
  • Load Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.
  • Safety Features: Over-temperature, over/under voltage, cooling-air loss, and current imbalance protection.
  • Load Connections: Copper Busbar, Camlock connectors are optional.
  • Daisy Chained: Multiple load banks can be hooked together for higher load capacity.
  • Enclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.
  • Weight: 1024kg
  • Size: 1900mm×1500mm×2000mm

 