• 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020
  • 500KW Water Cooled Load Bank for Data Center Testing IMAX8020

500KW Water Cooled Load Bank for Data Center Testing IMAX8020

The 500KW Water Cooled Load Bank features with max 500KW power, and the rated voltage can be customized. It uses water as a refrigerant to cool down, which can reduce...


Brand: Emax
SKU: IMAX8020

The 500KW Water Cooled Load Bank features with max 500KW power, and the rated voltage can be customized. It uses water as a refrigerant to cool down, which can reduce energy consumption by 30%-50% and reduce noise by 20-35db. Equipped with professional host computer programming software, independently developed by EMAX. This software offers lifetime free upgrades and maintenance, ensuring long-term reliability and seamless performance.

Specifications:

  • Rated Power: 500KW
  • Rated Voltage: 380V/400V/415V AC
  • Working Cycle: Continuous operation.
  • Load Accuracy: ±3%
  • Remote Control: RS485, Modbus-RTU, using free software for remote control using a customer provided laptop, PC, or tablet.
  • Instrumentation: Digital metering (V, A, kW) and data logging.
  • Control Power: External power
  • Cooling System: Water Cooling, bottom inlet, up outlet
  • Noise: 60dB3M
  • Load Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.
  • Safety Features: Over-temperature, over/under voltage, cooling-air loss, and current imbalance protection.
  • Load Connections: Copper Busbar, Camlock connectors are optional.
  • Daisy Chained: Multiple load banks can be hooked together for higher load capacity.