{"product_id":"rlc-load-bank-anti-island-testing-120kw-400vac-imax3312-copy","title":"250kW RLC Load Bank Anti Island For Inverter Testing 400VAC-IMAX3330","description":"\u003cdiv data-page-id=\"WgaRdwXD1odUqcxwfsacLu8EnGc\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OsNhfTIwvds5chc3MAtcQW8unuA\"\u003eEMAX 250kW RLC Load Bank with Anti-Islanding Function is professional testing equipment for inverter testing. It simulates real grid load via RLC combination, focusing on verifying the grid-tied inverter’s anti-islanding protection and overall performance.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-OsNhfTIwvds5chc3MAtcQW8unuA\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KoddfxxgFdpJbZcMx05cw8RJn7T\"\u003eCustomizable in power and voltage, it adopts top-brand electrical accessories (Siemens, ABB, Schneider) for stable long-term operation and low maintenance.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-KoddfxxgFdpJbZcMx05cw8RJn7T\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Wn2vfbJxSdtUcrcEtk2cM4Cbn1b\"\u003eWith self-developed patented software, it provides accurate test data. Trusted by renowned customers like Intertek, ECO FLOW, and KSTAR.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-Wn2vfbJxSdtUcrcEtk2cM4Cbn1b\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"p\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecifications: \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"p\"\u003e\u003cspan\u003eMax Power: 250kW\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p\"\u003e\n\u003cspan\u003eRated Voltage: 380V\/400V\/415V\/480 AC\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eWorking Cycle: Continuous operation.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Accuracy: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eRemote Control: Modbus-RTU RS485, Modbus TCP\/IP\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e,\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e using free software for remote control using a customer-provided laptop, PC, or tablet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eControl method: 1. Three phases can be independently adjustable;\u003cbr\u003e2. Independently adjustable resistive capacitance;\u003cbr\u003e3. Power adjustment can be automatically performed through software\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eLoad step: Resistive load step: minimum 10W, maximum 20kW\u003cbr\u003eInductive load step: minimum 10VAR, maximum 20kVAR\u003cbr\u003eCapacitive load step: minimum 10VAR, maximum 20kVAR\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eCooling System: Integral forced-air cooling system, bottom\/side inlet, up outlet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eNoise: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e≤\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e82dB\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e（\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3M\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e）\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Connections: Copper Busbar, Camlock connectors are optional.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eWeight: 1400kg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eSize: 1900mm×1800mm×2000mm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47581002203188,"sku":null,"price":15200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/250KW_1.jpg?v=1773629720","url":"https:\/\/emaxloadbank.com\/products\/rlc-load-bank-anti-island-testing-120kw-400vac-imax3312-copy","provider":"Emaxloadbank.com-Top Load Bank Manufacturer","version":"1.0","type":"link"}