{"title":"Feature Products","description":"\u003cp\u003eEmax feature products for generator testing, data center testing, UPS testing.,etc\u003c\/p\u003e","products":[{"product_id":"600kw-load-bank","title":"600kW 380V\/400V\/415V\/480V AC Load Bank Outdoor 3 Phases EA3161AF","description":"\u003cp\u003eThe \u003cstrong\u003e600kW AC Resistive Load Bank\u003c\/strong\u003e is an outdoor version with a rainy cover, the control room can meet IP54 waterproof level. The fan is vertical, side intake and side exhaust. HMI, control buttons are integrated in a separate control room for easy operation. Engineered to simulate real-world operational conditions, this load bank delivers a controlled, reliable load to validate the performance, efficiency, and reliability of your power systems. It ensures that your equipment operates at peak performance and adheres to industry standards.\u003cstrong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecifications:\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eRated Power: 600KW\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eRated Voltage: 380V\/400V\/415V\/480V AC.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eWorking Cycle: Continuous operation.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eLoad Accuracy: \u003c\/span\u003e\u003cspan style=\"font-family: 宋体;\"\u003e±\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003e3%.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eRemote Control: Modbus RS485\/RJ45 for host computer, free software for remote control using a customer provided laptop, PC, or tablet.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eControl Power: Via external power or internal power.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eCooling System: Integral forced-air cooling system, bottom inlet, up outlet.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eNoise: \u003c\/span\u003e\u003cspan style=\"font-family: 宋体;\"\u003e≤\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003e70dB(\u003c\/span\u003e\u003cspan style=\"font-family: Calibri;\"\u003e3M).\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eWaterproof: IP54(Control room).\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eLoad Connections: Copper Busbar, Camlock connectors are optional.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":45669861883956,"sku":"EA3161AF","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/500KW_5.jpg?v=1775871416"},{"product_id":"500kw-water-cooled-load-bank-for-data-center-testing","title":"500KW Water Cooled Load Bank for Data Center CDU Testing EA7161S","description":"\u003cp\u003eThe \u003cstrong\u003e500KW \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/water-cooled-load-banks\" title=\"Water Cooled Load Bank\"\u003eWater Cooled Load Bank\u003c\/a\u003e \u003c\/strong\u003efeatures a maximum 500 kW power, and the rated voltage can be customized. It uses water as a refrigerant to cool down, which can reduce energy consumption by 30%-50% and reduce noise by 20-35db. Equipped with professional host computer programming software, independently developed by EMAX. This software offers lifetime free upgrades and maintenance, ensuring long-term reliability and seamless performance.\u003c\/p\u003e\n\u003ch3 class=\"p\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecifications: \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"p\"\u003e\n\u003cspan\u003eRated Power: 500KW\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"p\"\u003e\u003cspan\u003eTank Quantity: 1PC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p\"\u003e\n\u003cspan\u003eRated Voltage: 380V\/400V\/415V AC\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eWorking Cycle: Continuous operation.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Accuracy: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eRemote Control: Modbus TCP\/IP, using free software for remote control using a customer-provided laptop, PC, or tablet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eControl Power: Internal power\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eCooling System: Water Cooling, bottom inlet, up outlet\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003ePressure relief valve: Included. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eNoise: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e≤\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e40dB\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eDimensions: 1500mm*1400mm*1750mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eSafety Features: Over-temperature, over\/under voltage, flow rate, pressure, and current imbalance protection.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Connections: Copper Busbar, Camlock connectors are optional.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eCategory: \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/water-cooled-load-banks\" title=\"CDU Testing Load Bank\"\u003eCDU Testing Load Bank\u003c\/a\u003e, Chiller Testing Load Bank, UPS commissioning Load Bank.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":45681504911412,"sku":"EA7161S","price":8500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/500KW_1.jpg?v=1753855470"},{"product_id":"100kw-portable-380v-ac-load-bank-imax3110","title":"100KW Portable 380V AC Resistive Load Bank Air Cooling EA3141A","description":"\u003cp\u003eThis 100kw load bank is equipped with extra-large air inlets and outlets, designed to efficiently reduce the temperature of the equipment, ensuring quick heat dissipation during operation. This load bank features a compact yet robust structure that optimizes space usage without compromising on performance. The design focuses on both functionality and aesthetics.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMax Power: 100KW\u003c\/li\u003e\n\u003cli\u003eVoltage: 380V AC 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003ePower Factor: 1\u003c\/li\u003e\n\u003cli\u003eRemote Control: Modbus RS485, using free software for remote control using a customer provided laptop, PC, or tablet.\u003c\/li\u003e\n\u003cli\u003e Instrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eMinimum load step: 1KW\u003c\/li\u003e\n\u003cli\u003eCooling System: Integral forced-air cooling system, front inlet, rear outlet.\u003c\/li\u003e\n\u003cli\u003eNoise: ≤70dB（3M）\u003c\/li\u003e\n\u003cli\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: Copper Busbar, Camlock connectors are optional.\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/li\u003e\n\u003cli\u003eWeight: 150kg\u003c\/li\u003e\n\u003cli\u003eSize: 730*850*1300mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":45695434358836,"sku":"EA3141A","price":1900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_3.jpg?v=1733211160"},{"product_id":"100kw-rcd-non-linear-400v-ac-load-bank-pf-0-6-1-imax53100","title":"100KW RCD Non linear 400V AC Load Bank For Battery UPS Testing EA3145A","description":"\u003cp\u003eRCD load is a nonlinear simulation load that can be used to test UPS power supplies, inverter power supplies, etc. to understand their true working ability when carrying nonlinear loads such as computers and network equipment. By accurately detecting the power output power and quality of the power supply, it can be avoided that it cannot drive the load or pollute the power grid during actual use, thereby ensuring power supply safety.\u003c\/p\u003e\n\u003cp\u003eThis equipment can meet three test methods: 1. A three-phase AC source (can meet the three-phase four-wire\/two-phase three-wire test requirements) 2. A single-phase AC source 3. Three independent single-phase AC sources\u003c\/p\u003e\n\u003ch3 class=\"p\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecifications: \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"p\"\u003e\u003cspan\u003eMax Power: 100kVA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p\"\u003e\n\u003cspan\u003eRated Voltage: 230V\/380V\/400V\/415V AC\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eWorking Cycle: Continuous operation.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Accuracy: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eRemote Control: RS485, Modbus-RTU\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e,\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e using free software for remote control using a customer provided laptop, PC, or tablet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003ePower Factor: 0.7~1 （adjustable）\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eCrest Factor: 2~3\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eLoad step: \u003cspan style=\"font-family: Calibri;\"\u003e100W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eCooling System: Integral forced-air cooling system, bottom\/side inlet, up outlet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eNoise: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e≤\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e70dB\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e（\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3M\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e）\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Connections: Copper Busbar, Camlock connectors are optional.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eWeight: 460kg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eSize: 950*1150*1750MM \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":45715485065268,"sku":"EA3145A","price":3200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/1_69017679-d9b9-456d-ae5f-1b9c4e1b21ba.jpg?v=1733825273"},{"product_id":"600kw-rlc-resistive-reactive-capacitive-load-bank","title":"600KW RLC Resistive Reactive Capacitive 415V 400V 480V AC 50Hz 60Hz Load Bank EA3164A","description":"\u003cp\u003eThis 600KW RLC load bank consists of three parts: resistance-inductance-capacitance load, protection system and control system, mainly including alloy resistors, AC reactors, AC capacitors, electrical parameter data acquisition system, control system, protection system, heat dissipation system, auxiliary control, spare parts facilities, etc. This load bank is an outdoor version and the control room can meet IP54 level. It adopts Siemens PLC control and can be controlled by third-party laptops, PC.,etc through TCP\/IP. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 600kW.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage\u003c\/strong\u003e: 415V 400V 480V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency\u003c\/strong\u003e: 50\/60Hz.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e: Rated for continuous operation.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLoad Step Resolution\u003c\/strong\u003e: 0.1kW, 0.2kW, 0.2kW, 0.5kW, 1kW, 1kW, 2kW, 5kW, 10kW , 10kW, 20kW, 50kW, 100kW, 200kW, 200kW (can be customized).\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLocal Controls\u003c\/strong\u003e: HMI.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eRemote Control:\u003c\/strong\u003e RS485, RJ45, using free software for remote control using a customer provided laptop, PC, or tablet.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eInstrumentation\u003c\/strong\u003e: Digital metering (V, A, kW) and data logging.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eControl Power\u003c\/strong\u003e: Control power via an internal dual voltage transformer or from an external 415V\/400V\/480V source.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCooling Power\u003c\/strong\u003e: Blower power from load or external 415V\/400V\/480V 3P source.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCooling System\u003c\/strong\u003e: Integral forced-air cooling system, bottom inlet, up outlet.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLoad Elements\u003c\/strong\u003e: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLoad Connections\u003c\/strong\u003e: Copper Busbar and Camlock connectors are optional.\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDaisy Chained:\u003c\/strong\u003e Up to 20pcs load banks can be hooked together for higher load capacity.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 1680mm×2680mm×2400mm\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":45747890815028,"sku":"EA3164A","price":7500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/8_7afa4c3f-c010-4959-a64e-4f4bf2cff966.jpg?v=1734916070"},{"product_id":"30kw-liquid-cooled-load-bank-rack-mounted-imax8330-with-remote-control","title":"30kW Liquid Cooled Load Bank Rack Mounted EA8141S With Remote Control","description":"\u003cp data-start=\"128\" data-end=\"400\"\u003eThis 30kW rack-mounted \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/water-cooled-load-banks\" title=\"Liquid Cooled Load Bank\"\u003eliquid-cooled load bank\u003c\/a\u003e is our latest R\u0026amp;D product, specially designed for data center applications. It features a high adjustment precision of 1kW and integrates key components including a PLC, pressure sensor, flow meter, and temperature sensor.\u003c\/p\u003e\n\u003cp data-start=\"402\" data-end=\"645\"\u003eThe system uses DN25 stainless steel water pipes and supports a maximum flow rate of 40LPM, making it suitable for testing a variety of data center equipment such as CDUs (Coolant Distribution Units), PDUs (Power Distribution Units), and more.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: -10℃~40℃\u003c\/li\u003e\n\u003cli\u003eOperating environment humidity: 0～95%\u003c\/li\u003e\n\u003cli\u003eDimensions: Height 6U, W483 * H264 * D800mm\u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 400V AC \/ Testing circuit.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInlet water temperature: 5-40℃\u003c\/li\u003e\n\u003cli\u003eLiquid connector: UQD or Tri-Clamps\u003c\/li\u003e\n\u003cli\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge. Cold-Plated style. \u003c\/li\u003e\n\u003cli\u003eSafety Features: Over\/under-liquid temperature, over\/under voltage,  overcurrent protection, over\/under flow rate, and over\/under liquid pressure.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: 5-pin IEC plug\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCategory: In Rack CDU Testing Load Bank, \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/water-cooled-load-banks\" title=\"DTC Liquid Load Bank\"\u003eDTC Liquid Load Bank\u003c\/a\u003e.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":46833548591156,"sku":"EA8141S","price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/1_2a764c11-b4f5-4e0d-821f-0837dc316874.jpg?v=1749626084"},{"product_id":"200kw-liquid-cooling-load-bank-rack-imax83200-with-manifold","title":"200kW Liquid Cooling Load Bank Rack EA6151S With Manifold","description":"\u003cp data-start=\"128\" data-end=\"400\"\u003eThe 200kW \u003cspan\u003eEA6151S\u003c\/span\u003e \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/water-cooled-load-banks\" title=\"Liquid cooled load bank\"\u003eLiquid Cooling Load Bank\u003c\/a\u003e Rack is designed to simulate the NVIDIA GB200, GB300, as required by our customers. It boasts a single energy density of 10kW\/U and is maintenance-free and capable of continuous operation.\u003c\/p\u003e\n\u003cp data-start=\"402\" data-end=\"645\"\u003eThe complete product package includes liquid cooling modules, cabinets, and a manifold, allowing customers to plug and play right after receiving the product. The entire system is less than 42U tall, making it easy to move. A central control panel controls all liquid cooling modules.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: -10℃~50℃\u003c\/li\u003e\n\u003cli\u003eLiquid direction: Bottom feed, right inlet\/left outlet\u003c\/li\u003e\n\u003cli\u003eHeat transfer fluid: 25% Propylene Glycol\/Pure water\u003c\/li\u003e\n\u003cli\u003eOperating environment humidity: 0～95%\u003c\/li\u003e\n\u003cli\u003eDimensions: Height 42U\u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 400V AC \/ Testing circuit.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInlet water temperature: 5-40℃\u003c\/li\u003e\n\u003cli\u003eDelta temperature \u0026lt; 12ºC\u003c\/li\u003e\n\u003cli\u003eCommissioning Scope: CDU commissioning, chiller commissioning, cooling tower commissioning, UPS commissioning, etc.\u003c\/li\u003e\n\u003cli\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, over\/under pressure, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: 5-core industry plug\/socket\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Heavy gauge steel indoor enclosure with powder-coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47065849692212,"sku":"EA6151S","price":15000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/200KW.jpg?v=1756719788"},{"product_id":"200kw-230vac-and-400vac-load-bank-with-camlock-for-generator-testing","title":"200KW 230VAC And 400VAC Load Bank With Camlock For Generator Testing EA3151A","description":"\u003cp\u003eThis 200kW load bank is specially used for generator testing, with a maximum power of 200kW and a minimum step power of 1kW, it can be remotely controlled by a host computer, supporting group control of up to 200 units. It uses stainless steel and nickel-chromium alloy resistors to ensure continuous operation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eLoad Accuracy: ±3%\u003c\/li\u003e\n\u003cli\u003ePower Factor: 1\u003c\/li\u003e\n\u003cli\u003eRemote Control: An external Ethernet port is provided to mimic the control screen using free software for remote control using a customer-provided laptop, PC, or tablet. Modbus RS485 or Modbus TCP\/IP. \u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 380~400V AC, 3P4W or 3P5W, 50Hz.\u003c\/li\u003e\n\u003cli\u003eCooling System: Integral forced-air cooling system, bottom inlet, up outlet IP54 rated.\u003c\/li\u003e\n\u003cli\u003eNoise: ≤85dB（3M）Indoor.\u003c\/li\u003e\n\u003cli\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: Copper Busbar, Camlock, Powerlock connectors are optional.\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47272288911412,"sku":"EA3151A","price":4000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/2_dfb65b4a-c8e4-4db1-858c-34334b893fd3.jpg?v=1763696710"},{"product_id":"100kw-portable-ac-dc-load-bank-for-generator-and-data-center-testing-imax3701","title":"100KW Portable AC\/DC Load Bank For Generator And Data Center Testing EA2141A","description":"\u003cp\u003eThis 100kW portable load bank is a compact load bank designed for indoor use, eliminating concerns about space constraints. It features helically wound chromium alloy heating elements, neatly arranged and supported by high-temperature mica. It also incorporates components from brands such as ABB, Siemens, and Schneider Electric. The airflow design features side intake and side exhaust, fully meeting the needs of portable generators and data center simulation testing.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eLoad Accuracy: ±3%\u003c\/li\u003e\n\u003cli\u003ePower Factor: 1\u003c\/li\u003e\n\u003cli\u003eRemote Control: An external Ethernet port is provided to mimic the control screen using free software for remote control using a customer-provided laptop, PC, or tablet. Modbus RS485 or Modbus TCP\/IP. \u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 110~240V AC, 3P4W or 3P5W, 50Hz.\u003c\/li\u003e\n\u003cli\u003eTesting Power: 380V\/400V\/415V\/480V\u003c\/li\u003e\n\u003cli\u003eCooling System: Integral forced-air cooling system, bottom inlet, up outlet, IP54 rated.\u003c\/li\u003e\n\u003cli\u003eNoise: ≤80dB（3M）Indoor.\u003c\/li\u003e\n\u003cli\u003eLoad Elements: Helically wound chromium alloy. The heating elements are supported by mica arrays and arranged compactly and regularly to achieve optimal air resistance and temperature rise.\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: Copper Busbar, Camlock, Powerlock connectors are optional.\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Portable steel indoor enclosure with powder coat finish. Equipped with four-way swivel casters at the bottom and a sturdy handle, mobility-friendly.\u003c\/li\u003e\n\u003cli\u003eWeight: 36kg\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cspan\u003eW295mm*D540mm*H655mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47289735512116,"sku":"EA2141A","price":2850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/100kWportableloadbanks_2.jpg?v=1764377162"},{"product_id":"200kw-rcd-non-linear-400v-ac-load-bank-for-testing-imax53200","title":"200KW RCD Non linear 400V AC Load Bank PF0.3~1 For Inverter Testing EA3155A","description":"\u003cp\u003e200KW RCD Non-linear AC Load Bank (Model: \u003cspan\u003eEA3155A\u003c\/span\u003e) is a high-performance testing equipment designed specifically for inverter testing, operating at 400V AC. Its power factor (PF) is continuously adjustable from 0.3 to 1.0, which can accurately simulate the actual working conditions of non-linear loads such as inverters, ensuring comprehensive and reliable testing results. Equipped with 3-phase independent adjustment function, it allows flexible adjustment of each phase load according to different testing requirements, effectively adapting to the performance testing needs of various types of inverters (including PV inverters, energy storage inverters, grid-tied inverters, etc.).\u003c\/p\u003e\n\u003cp\u003eThis load bank is widely used in inverter factory testing, type testing, and on-site debugging, providing stable and precise load simulation support for verifying inverter load-carrying capacity, harmonic performance, dynamic response, and operational stability.\u003c\/p\u003e\n\u003ch3 class=\"p\"\u003e\n\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003eSpecifications: \u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli class=\"p\"\u003e\u003cspan\u003eMax Power: 200kVA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"p\"\u003e\n\u003cspan\u003eRated Voltage: 230V\/380V\/400V\/415V AC\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eWorking Cycle: Continuous operation.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Accuracy: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e±\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3%\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eRemote Control: Modbus-RTU (RS485), Modbus TCP\/IP \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: Calibri;\"\u003e,\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e using free software for remote control using a customer provided laptop, PC, or tablet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003ePower Factor: 0.3~1 （adjustable）\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003eLoad step: \u003cspan style=\"font-family: Calibri;\"\u003e100W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eCooling System: Integral forced-air cooling system, bottom\/side inlet, up outlet.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eNoise: \u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e≤\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e82dB\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e（\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e3M\u003c\/span\u003e\u003cspan\u003e\u003cspan style=\"font-family: 宋体;\"\u003e）\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Elements: High-capacity Nichrome load elements. Elements are fully supported with stainless steel rods and high-temperature refractory ceramics for quick heat discharge.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eLoad Connections: Copper Busbars.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\n\u003cspan\u003eEnclosure: Heavy gauge steel outdoor enclosure with powder coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eWeight: 680kg\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e\u003cspan\u003eSize: 1150*1350*1750MM \u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47580989456436,"sku":"EA3155A","price":8500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/1_fe385545-5049-4947-a9d4-f9330a7c87c5.jpg?v=1773628747"},{"product_id":"10kw-20kw-rack-mounted-load-bank-for-ups-and-data-center-testing-imax3002","title":"10kW\/20kW Rack Mounted Load Bank for UPS And Data Center Testing EA1121S","description":"\u003cdiv data-page-id=\"P281dRI86oNhT0xvPtlcvJzan0f\" data-lark-html-role=\"root\" data-docx-has-block-data=\"false\"\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-YsptfIXSadtDQ4cEJxYcIu85nVh\"\u003eThis is the latest rack-mounted air-cooled load bank designed by EMAX, mainly tailored for the testing of data center backdoor air conditioners. Boasting high power density and ultra-low temperature rise, it can also meet the testing requirements of UPS and generators, delivering versatile performance for multiple scenarios.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-YsptfIXSadtDQ4cEJxYcIu85nVh\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-R966fDlaqdLAdRcemMEczxM7nbg\"\u003eOperation is extremely convenient, available in two versions: remote control and local control, allowing flexible operation according to on-site needs. Parallel expansion is simple and hassle-free, enabling easy capacity expansion to adapt to different testing scales.\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-R966fDlaqdLAdRcemMEczxM7nbg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"ace-line ace-line old-record-id-QWPYfeCJHdziLOcy0CPc650QnJ0\"\u003eIt is equipped with an alarm and protection for temperature, current, voltage, and power, providing real-time monitoring of equipment operation status and clear records of abnormal conditions. The EPO one-key unloading function ensures safe and quick shutdown in emergency situations, maximizing operational safety.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eLoad Accuracy: ±3%\u003c\/li\u003e\n\u003cli\u003ePower Factor: 1\u003c\/li\u003e\n\u003cli\u003eRemote Control: An external Ethernet port is provided to mimic the control screen using free software for remote control using a customer-provided laptop, PC, or tablet. Modbus RS485 or Modbus TCP\/IP. \u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 110~240V AC, 3P4W or 3P5W, 50Hz.\u003c\/li\u003e\n\u003cli\u003eTesting Power: 230V380V\/400V\/415V\/480V\u003c\/li\u003e\n\u003cli\u003eCooling System: High air flow volume EC fans\u003c\/li\u003e\n\u003cli\u003eNoise: ≤92dB（1M）Indoor.\u003c\/li\u003e\n\u003cli\u003eLoad Elements: Helically wound chromium alloy. The heating elements are supported by mica arrays and arranged compactly and regularly to achieve optimal air resistance and temperature rise.\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, cooling-air loss, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: Cee form, C14, C20\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Portable steel indoor enclosure with powder coat finish. \u003c\/li\u003e\n\u003cli\u003eWeight: 30kg\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cspan\u003eW483mm*D800mm*H266mm -6U\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47638022357044,"sku":"EA1121S","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/rack_mounted_load_banks_1.jpg?v=1774669804"},{"product_id":"300kw-800vdc-rubin-liquid-cooled-load-bank-rack-with-group-control-imax83300","title":"300kW 800VDC Rubin Liquid Cooled Load Bank Rack With Group Control EA6451A","description":"\u003cdiv\u003eThe EA6451A is a 300kW \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/liquid-cooled-load-banks\" title=\"Liquid cooled load bank\"\u003eliquid-cooled load bank\u003c\/a\u003e rack specifically designed to simulate the \u003cstrong\u003eNVIDIA Rubin 800VDC platform\u003c\/strong\u003e. It features a high energy density of 10kW\/U, maintenance-free construction, and reliable continuous operation. Housed in a compact \u0026lt;57U rack with integrated liquid cooling modules, manifold, and cabinet, the system delivers true plug-and-play deployment and easy mobility. A centralized control panel enables intelligent monitoring and control of all load modules.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eBuilt on \u003cstrong\u003e800VDC high-voltage architecture\u003c\/strong\u003e, the solution reduces copper cable usage by up to 45% and minimizes PDU footprint while lowering current and thermal losses compared to 415V AC or 54VDC systems. It improves end-to-end efficiency by up to 5% over legacy 54V systems.\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe platform supports seamless scalability from 100kW to over 1MW using standard data center infrastructure. By relocating power conversion outside the rack, it enhances thermal performance, system reliability, and long-term durability while eliminating frequent maintenance. Future-proofed for next-generation 1MW racks, the EA6451A provides a stable, efficient, and scalable testing solution for high-power data center and AI hardware validation.\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: -10℃~50℃\u003c\/li\u003e\n\u003cli\u003eLiquid direction: Bottom feed or Top feed, right inlet\/left outlet\u003c\/li\u003e\n\u003cli\u003eHeat transfer fluid: 25% Propylene Glycol\/Pure water\u003c\/li\u003e\n\u003cli\u003eOperating environment humidity: 0～95%\u003c\/li\u003e\n\u003cli\u003eDimensions: Height 57U\u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 400V AC \/ Testing circuit.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInlet water temperature: 5-40℃\u003c\/li\u003e\n\u003cli\u003eDelta temperature \u0026lt; 12ºC\u003c\/li\u003e\n\u003cli\u003eHeating Elements: Cold-Plated\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, over\/under pressure, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: 5-core CEE form IEC60309 Plug or Camlock\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Heavy-gauge steel indoor enclosure with powder-coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47650200387636,"sku":"EA6451A","price":20000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/300kW.jpg?v=1775126066"},{"product_id":"120kw-132kw-liquid-cooled-load-bank-for-data-center-testing-ea6141s","title":"120kW\/132kW Liquid Cooled Load Bank for AI Data Center Testing EA6141S","description":"\u003cdiv\u003eThis rack-level \u003ca href=\"https:\/\/emaxloadbank.com\/collections\/water-cooled-load-banks\" title=\"AI Liquid cooled load bank\"\u003eliquid-cooled load bank\u003c\/a\u003e is engineered to simulate the latest AI liquid-cooled servers. It adopts the identical cold plate liquid cooling solution deployed on physical production servers, delivering an effective thermal power efficiency of over 95%. \u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eDesigned on a modular architecture, each individual power module has a rated capacity of 20kW, with a thermal response time within 30 seconds to achieve a stable output P-Thermal.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eIt is fitted with 63A Ceeform electrical connectors complying with IEC60309 standards, while FD83 quick couplings serve as the liquid circuit connections. The unit is built to a 1:1 scale replication of standard server racks.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003eEvery liquid module features UQD connectors that support hot swapping without system shutdown. An integrated fluid manifold is equipped to the whole Rack, keeping flow deviation across all branches below 3%.\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eWorking Cycle: Continuous operation.\u003c\/li\u003e\n\u003cli\u003eAmbient temperature: -10℃~50℃\u003c\/li\u003e\n\u003cli\u003eLiquid direction: Bottom feed or Top feed, right inlet\/left outlet\u003c\/li\u003e\n\u003cli\u003eHeat transfer fluid: 25% Propylene Glycol\/Pure water\u003c\/li\u003e\n\u003cli\u003eOperating environment humidity: 0～95%\u003c\/li\u003e\n\u003cli\u003eDimensions: Height 33U\u003c\/li\u003e\n\u003cli\u003eInstrumentation: Digital metering (V, A, kW) and data logging.\u003c\/li\u003e\n\u003cli\u003eControl Power: Via external 400V AC \/ Testing circuit.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInlet water temperature: 5-40℃\u003c\/li\u003e\n\u003cli\u003eDelta temperature \u0026lt; 12ºC\u003c\/li\u003e\n\u003cli\u003eHeating Elements: Cold-Plated\u003c\/li\u003e\n\u003cli\u003eSafety Features: Over-temperature, over\/under voltage, over\/under pressure, and current imbalance protection.\u003c\/li\u003e\n\u003cli\u003eLoad Connections: 5-core CEE form IEC60309 Plug or Camlock\u003c\/li\u003e\n\u003cli\u003eDaisy Chained: Multiple load banks can be hooked together for higher load capacity.\u003c\/li\u003e\n\u003cli\u003eEnclosure: Heavy-gauge steel indoor enclosure with powder-coat finish. Hinged access doors with lockable latches. Forklift pockets for easy mobility.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank.png?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_1.jpg?v=1732669788\" alt=\"\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/photobank_2.jpg?v=1732669889\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\n        table,table tr th, table tr td { border:1px solid #0094ff; }\n        table { width: 200px; min-height: 25px; line-height: 25px; text-align: center; border-collapse: collapse; padding:2px;}   \n      \n    \u003c\/style\u003e","brand":"Emax","offers":[{"title":"Default Title","offer_id":47846874742836,"sku":"EA6141S","price":12000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/files\/1-1.jpg?v=1780112777"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9831\/9668\/collections\/200KW.jpg?v=1764326415","url":"https:\/\/emaxloadbank.com\/collections\/feature-products.oembed?page=2","provider":"Emaxloadbank.com-Top Load Bank Manufacturer","version":"1.0","type":"link"}